Please use this identifier to cite or link to this item:
http://210.212.227.212:8080/xmlui/handle/123456789/98| Title: | Environmental forensic investigation of the air pollution from a cement manufacturing unit |
| Authors: | Muhammed Siddik, A |
| Keywords: | Air pollution suspended particulate matter environmental forensics forensic investigation guideline cement factory GIS |
| Issue Date: | 6-Dec-2019 |
| Citation: | Muhammed Siddik Abdul Samad, Prem Mohan, George K. Varghese, Irfan Khursheed Shah & Babu J. Alappat (2019): Environmental forensic investigation of the air pollution from a cement manufacturing unit, Environmental Forensics |
| Abstract: | Cement manufacturing is a process that results in the emission of significant quantities of suspended particulate matter (SPM) to the ambient air. An environmental forensic investigation was carried out in the surroundings of a major cement manufacturing unit at a place called Coimbatore in the southern Indian state of Tamil Nadu. The investigation was carried out to identify the contribution of the cement manufacturing unit to the SPM concentration of the surrounding air environment. The sampling points’ selection and sample collection were done following the principles outlined in the INTERPOL Manual for Pollution Crime Forensic Investigation. On-site monitoring of the air samples was carried out using Mini Laser Aerosol Spectrometer (GRIMM, Mini-LAS Model 11R). The instrument was capable of measuring particles ranging from 0.25 to 32 mm and classifying them into 31 size channels. The test results at majority of the monitoring locations were well above the limits specified in the National Ambient Air Quality Standards of India. Microscopic studies of the dust samples were carried out for surface texture and particle shape. The spatial distribution of particles was analysed using geographic information system (GIS) for the visual identification of the extent of the pollution by keeping the cement factory as the focal point. The results from the GIS and microscopic analysis established the role of the cement factory in the particulate matter pollution of its surroundings, specifically in the areas North-West of the factory. The successfully adopted procedure can serve as a guideline for the environmental forensic investigation of similar pollution incidences. |
| URI: | 10.1080/15275922.2019.1694094 http://localhost:8080/xmlui/handle/123456789/98 |
| Appears in Collections: | Journal Articles |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| abdulsamad2019.pdf | 2.2 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.